PT Chart & Charge Calculators

PT Chart

Saturation pressures for six common refrigerants, plus superheat, subcooling, and a quick system diagnose — computed from real refrigerant properties, right on your phone.

How it works: pick a refrigerant and enter a temperature to get bubble and dew pressures. Use the dew point for superheat and the bubble point for subcooling — for pure refrigerants they're identical; for blends like R-454B they differ by the temperature glide.
Reference tool, not a charging procedure. Always follow the equipment manufacturer's charging procedure and verify with calibrated gauges. Pressures below 0 psig are vacuum — normal at low temperatures.

PT lookup

Saturation pressure at a temperature. Bubble = liquid starts boiling · Dew = vapor starts condensing.

Superheat

Suction-line temp minus the dew-point saturation temp at suction pressure. Typical TXV target: 8–12°F.

Subcooling

Bubble-point saturation temp at head pressure minus the liquid-line temp. Typical target: 8–12°F (follow the nameplate).

Quick diagnose

Enter your gauge and thermometer readings. The tool computes superheat, subcooling, and condenser approach, then tells you what to check first — in plain language.